Laser marking: mechanisms, lasers and shortlist
A shortlist guide for engineers and buyers who need permanent marks without consumable inks: what laser marking is, which mechanism fits the part, which laser class fits the material, and how to shortlist suppliers before RFQs.
Supplier directory · By Photonics Map · reviewed 2026-10
- Typical average power
- Order of 10 W to 100 W for many stations
- Common wavelengths
- ~10 µm (CO₂), ~1 µm (fiber / Nd:YAG), 532 nm, UV / excimer
- Engraving depth
- Often below ~100 µm; deeper when the job needs it
- Patterning
- Galvo scan (vector or raster); masks less common now
- Defining tradeoff
- Absorption and threshold vs speed and contrast
Who this guide is for
Process, packaging, electronics and medical-device buyers who already know they need laser marks (serials, logos, codes, decorative graphics) and need to pick a mechanism and laser class. If you only need a supplier list, use the category hub linked at the end.
What laser marking is
Laser marking is a group of laser material-processing methods that permanently label an object by changing how its surface looks, or by removing a little material. The beam may ablate a shallow groove (engraving), strip a coating or oxide layer, or modify the surface (for example oxidation on metal, carbonization or foaming on polymers) so contrast appears without deep cutting. Compared with inkjet or mechanical stamps, laser marks need no consumable ink, stay durable, and scale to tiny features and variable data, at the cost of a dedicated laser station.
Which marking mechanism fits
| Regime | Pulse | Strength | Choose when |
|---|---|---|---|
| Engraving (ablation) | Usually pulsed; depth often under ~100 µm | Clear tactile / visual groove; works on many solids | You need depth, wear resistance, or a mark that survives coatings and cleaning. Plan for fumes and longer cycle time than surface-only marks. |
| Layer removal | Ablate paint, ink, or anodize only | High contrast by revealing the substrate color | Anodized aluminum, painted parts, or coated films where stripping the top layer is enough and you must not dig into the bulk. |
| Surface modification | Heat / chemistry change, little removal | Annealing colors, polymer blackening or foaming | You want contrast without a deep groove: oxide colors on metal, carbonized black on many plastics, or lighter raised marks where the polymer expands. |
| In-volume (transparent) | Tight focus inside glass / crystal | Sub-surface spots via breakdown | Decorative or security marks inside glass where surface polish must stay intact. Needs careful focusing and usually shorter pulses than shop-floor anneal marks. |
Specs that actually change results
| Specification | Typical | Why it matters |
|---|---|---|
| Wavelength and absorption | ~10 µm CO₂; ~1 µm fiber / Nd:YAG; 532 nm; UV / excimer | The material must absorb enough at process intensity. Metals usually need ~1 µm (or shorter for gold and similar); plastics, wood, paper and acrylic often work with sealed CO₂. Marking intensities are moderate, so you cannot rely on strong anomalous absorption the way some deep ablation processes do. |
| Fluence, spot and threshold | Process-dependent threshold; tight focus for fine features | Many marking processes fail below a material- and mechanism-specific threshold even with many pulses. Spot size sets both intensity and feature size; working distance and depth of focus decide whether 3-axis focus tracking is needed on curved parts. |
| Beam quality (M²) | Near diffraction-limited preferred for fine marks | High beam quality supports a small focused spot at a usable working distance. Poor M² forces larger spots or shorter working distance and can kill barcode readability at small sizes. |
| Pulse energy, duration and rate | Q-switched ns class common; MOPA can vary duration vs rate | Average power is roughly energy × rate. High rate helps throughput; pulse duration and peak intensity change HAZ and contrast (short pulses for fine metal anneal / black marks; longer, more energetic pulses for deeper engraving). Basic Q-switched sources couple duration to rate; fiber MOPA systems often set them more independently. |
| First-pulse control | Suppression or shaping after scan pauses | Restarting a Q-switched train after a move can dump excess energy into the first pulse and spoil contrast. Ask whether the source offers first-pulse suppression if your job has many jump-and-mark segments. |
| Field size, cooling and packaging | f-theta field; air cooling common at modest power | Marking field, fixturing and fume extraction dominate integration cost. Air-cooled heads suit many tens-of-watts jobs; harsh factories need vibration and back-reflection tolerance as much as peak power. |
Architectures
- 01
Sealed CO₂ lasers
Long-wave (~10 µm) sealed CO₂ sources are common on plastics, wood, cardboard, paper, leather and acrylic. Many jobs run continuous-wave or gently pulsed at modest power. Metals reflect strongly at this wavelength, so CO₂ is usually the wrong first pick for bare metal marks.
- 02
Q-switched solid-state (~1 µm)
Lamp- or diode-pumped Nd:YAG / vanadate Q-switched lasers deliver nanosecond pulses near 1 µm, where many metals absorb better than at CO₂ wavelengths. Vanadate designs can favor high repetition rates (above ~100 kHz) when that helps scan speed.
- 03
Fiber lasers and fiber MOPA
Fiber sources in the 1 µm class are compact and robust for industrial metal and some polymer marks. MOPA architectures (seed plus fiber amplifiers) often allow independent pulse duration and repetition rate, useful when the same station must anneal, black-mark and deep-engrave. Pulse energies and peak powers may be lower than some bulk Q-switched heads; match the mechanism, not the brochure label.
- 04
Green, UV and excimer
Frequency-doubled ~532 nm helps metals that absorb poorly at 1 µm (gold is a classic case), at the cost of conversion efficiency and complexity. Excimer and other UV sources appear when glasses, ceramics or specialty polymers need short-wavelength absorption. Treat these as special cases, not the default shop-floor buy.
- 05
Scanner station vs mask
Most modern markers use galvo scanners with an f-theta lens: vector paths for text and codes, raster fills for graphics. Mask imaging can stamp a whole pattern in one shot but needs a physical mask per artwork and wears out; flexibility usually wins for variable serials and barcodes. On-the-fly marking on a moving line needs encoder sync and a process window that tolerates motion.
Applications snapshot
Industrial & automotive
Metal traceability and branding
Serials, Data Matrix codes and logos on steel, aluminum and tooling. Ask for contrast after passivation or coating, corrosion behavior of anneal marks, and sample codes at your smallest module size.
Consumer & electronics
Anodized and coated aluminum
Often layer removal through the anodize or paint rather than deep engraving. Specify coating stack and whether the substrate color under the coating is acceptable as the mark.
Packaging & consumer goods
Plastics and packaging
Date codes, lot marks and branding on polymers, films, cardboard and bottles. CO₂ is common; some plastics need additives or a different wavelength for reliable contrast. Ask about smoke extraction and food-contact rules if relevant.
Semiconductor & electronics
Electronics and wafers
PCB identifiers, IC packages and wafer / boule traceability marks. Feature size, heat into the die and residue matter more than raw watts. Require sample marks on your stack-up.
Medical & specialty
Glass, ceramics and medical devices
Surface or sub-surface marks on glass and ceramics, plus UDI-style marks on instruments and implants. Mechanism and wavelength are material-specific; validate sterilisation and biocompatibility effects with the vendor and your QA team.
How to choose
- 01
Start from material and contrast goal
Write down substrate, coatings, required permanence, and whether the mark may be recessed. That decides mechanism (engrave vs strip vs anneal) before you pick watts or a brand.
- 02
Match wavelength to absorption
CO₂ for many organics; ~1 µm fiber or Nd:YAG for most metals; green or UV when 1 µm absorption is too weak. Do not buy a metal fiber marker for cardboard just because it is popular.
- 03
Buy pulse control when the process needs it
If one station must switch between fine anneal marks and deeper engraving, favor sources that can change pulse duration and rate independently (often fiber MOPA). If the job is one fixed recipe, a simpler Q-switched head may be enough.
- 04
Plan fixturing, fumes and safety with the laser
Enclosure class, exhaust, and how parts present to the field often cost as much as the source. On-the-fly lines need motion sync proven on your conveyor, not only on a demo fixture.
How to shortlist suppliers
- 01
Lock the process sheet
Material, coating, mark type (code / logo / decorative), minimum feature size, permanence tests, throughput target and whether marks run on the fly. Vendors should quote against that sheet.
- 02
Decide head vs station vs job shop
Buy an OEM head if you already integrate scanners and motion. Buy a turnkey class-1 station if you need a guarded cell. Use a contract marker when volume is low or the recipe is still changing.
- 03
Require sample marks on real parts
Judge contrast, HAZ, code grade and post-process survival (passivation, autoclave, abrasion) on your parts. Datasheet power alone does not predict readability.
- 04
Ask about first pulse, service and optics life
First-pulse behavior, scan-head windows, f-theta contamination and diode or tube lifetime drive uptime. Compare five-year service, not only list price.
- 05
Browse suppliers on the hub
Once the mechanism and laser class are clear, use the laser marking suppliers directory to see who lists marking and engraving systems, then request quotes against your process sheet.
Ready to browse companies? Open the supplier hub.
Frequently asked questions
›What is the difference between laser marking and laser engraving?
Engraving is marking by ablating material to a visible depth. Other marking methods only change the surface (color, texture or a thin layer) with little bulk removal. Buyers often say “marking” for the whole family and “engraving” when they need a groove.
›Why not just use inkjet?
Laser marks need no ink consumables, resist many solvents and abrasion, and scale to very small features and per-part data. Inkjet can be cheaper to start and gentler on some soft packs; choose on permanence, contamination rules and cost of ownership, not slogans.
›Which laser marks metal best?
Sources near 1 µm (fiber or Nd:YAG Q-switched) are the usual metal markers because absorption is much better than at CO₂ wavelengths. Gold and some other metals may need green or another shorter wavelength. Always confirm with sample marks.
›When should I choose a CO₂ marking laser?
When the part is an organic or polymer-like material that absorbs ~10 µm light well: many plastics, wood, paper, cardboard, leather and acrylic. It is a weak default for bare metals.
›What is a fiber MOPA marker?
A master-oscillator power-amplifier fiber source that seeds a pulse and amplifies it in fiber stages. Many MOPA markers let you set pulse duration and repetition rate more independently than a basic Q-switched laser, which helps when one machine must cover anneal and deep-engrave recipes.
›Why do vendors talk about first-pulse suppression?
After a pause in a Q-switched pulse train, the next pulse can be stronger than the rest and burn the start of a character or code. Suppression or shaping keeps mark quality even when the scanner jumps between fields.
›How much average power do I need?
Many industrial marking stations work in the rough range of tens of watts (order of 10 W to 100 W); high-throughput lines may use more. Power only helps if wavelength, spot and pulse shape already clear the process threshold. Size power from sample cycle time, not from a round number on a brochure.
›Do I need a galvo scanner or a mask?
Galvo scanning dominates when artwork or serial data changes often. Mask imaging can be fast for a fixed pattern but needs tooling per design and is less common for variable codes. Most buyers shortlist scanner-based stations unless they have a fixed, high-volume stamp job.
Sources
- RP Photonics Encyclopedia: Laser marking · mechanisms, materials, scanner vs mask, laser demands
- RP Photonics Encyclopedia: Laser ablation · engraving as ablation; threshold and pulse-length intuition
- RP Photonics Encyclopedia: Fiber lasers · fiber sources and MOPA architecture
- RP Photonics Encyclopedia: CO₂ lasers · long-wave sources for many non-metals
- RP Photonics Encyclopedia: Q-switching · nanosecond pulsed solid-state marking sources
- RP Photonics Encyclopedia: M² factor · beam quality and focusability for fine marks
Figures are the commercially common cases, not physics records. Where sources disagree the page gives a range and says so.